Why are precision and accuracy different goals for a robot?
Precision concerns how closely repeated results agree under stated conditions. Accuracy concerns their agreement with a reference or intended position. A robot may consistently reach one point while that point is displaced from its actual target.
Measuring only one result or averaging away the variation can conceal the difference. The corrective action depends on whether the positions scatter, shift as a group, or both.
Start with the question
The answer, the explanatory gap and useful foundations.
Read in your own way
Start with the answer, refresh a foundation when you need it, or follow the explanation through. Read the ordered explanatory sections and check their stated sources and limits.
Everything here is open without an account. Saving is optional. The public subject tree is a map of published ideas; My Forest contains the subjects you choose to plant.
See the public Robotics & Automation tree →A foundation, without a detour.
Suppose a robot moves a pen tip along one axis. A separate reference scale can locate the tip when it stops. Use that independent location to compare trials.
The reference has its own uncertainty
A reference scale can support a comparison when its value and uncertainty are known well enough. It does not become exact simply because we call it the target.
Develop the model
Follow the first explanatory steps without losing their qualifications.
Ask the pen to reach the same mark
Imagine asking a tabletop drawing robot to place a dot at 50 mm along a measured axis. Under the same stipulated start, load and speed, series A ends at 53.8, 54.0 and 54.2 mm. Series B ends at 48.0, 50.0 and 52.0 mm. These readings are invented to separate two kinds of behavior, not data from a named robot.
The marks in A span 0.4 mm and their mean is 54.0 mm. They agree closely with each other but all miss the reference on the same side. The marks in B span 4.0 mm and their mean is 50.0 mm. The group has a mean on the target but individual outcomes can miss it by 2 mm. The spread and the displacement are different observations.
A tight cluster can miss its target, and a centered mean can hide spread.
State what was kept the same
Repeatability refers to agreement under specified repeated conditions. If the pen moves to the mark from different directions, gear play or compliance might make one series end differently from another. Warming or changing the load could have a different effect. Each result is only meaningful with the start, method, equipment and conditions named.
The test also needs an independent way to locate the dot. A readout can claim the joint reached its internal zero even when the tip is shifted. If the reference shares the same offset as the robot’s coordinate model, it can hide a real error. Measure the result in the coordinate system that defines the task.
State the repeat conditions and measure against the reference that matters.
Investigate and refine
Predict, compare the lenses and carry the explanation further.
The next sections refine the explanation. No interactive investigation has been attached to this publication.
Test an explanation for each pattern
For A, one hypothesis is a reference origin that has shifted relative to the paper. A careful calibration at several marks can check it. Subtracting 4 mm everywhere after just one test might fix one point while worsening others. A reference offset, a scaled coordinate and a bent pen holder make different predictions over the full test range.
For B, moving the whole distribution does little to shrink it because its mean is already near 50. Variation could come from shaking, changing contact or an unstable stop condition. Repeating the measurements with one condition changed can help distinguish causes. Priors about a machine can guide the test, but the spread alone does not assign a cause.
Check systematic displacement and trial-to-trial variation with different experiments.
Choose metrics for the actual goal
If a single dot must land within half a millimeter, neither set satisfies the stipulated goal on all three trials. If many dots are averaged in a harmless measurement, the average may reduce some independent random variation but cannot remove a persistent bias. Your decision depends on what counts as success for the work and how many chances there are to observe failure.
A useful report says which reference was used, how trials were repeated and what spread and displacement were measured. Calling the robot precise without naming a condition or metric leaves out the evidence that someone needs to judge whether a different task would work.
Report actual positions, their spread and reference disagreement in relation to the task.
Apply and connect
Try a new case, follow genuine relationships and check the sources.
Consider another case.
How could measuring from both directions show a repeatable shift that a one-direction test would miss?
No assessment item is attached. Reading or marking this explanation studied does not award assessment evidence.
A useful explanation has edges.
- The original numbers are simplified one-dimensional examples with a stipulated reference and do not constitute a qualified robotics test.
- Range is used as an introductory summary of spread. It is not a complete estimate of measurement uncertainty.
Follow the concepts.
A map can help you find a useful foundation or a different view. Every line below has a stated reason and a limit.
No direct published relationship is recorded for this selection yet. No connection is invented to fill the diagram.
Find a connected question with Seed Shuffle →Sources & authorship
This explanation was released through an explicit editorial review. Structural checks and an Owner or delegated editorial decision are not independent expert or scientific certification.
The sources below identify claim scope and consultation dates. Check the original material and its limits.
- NIST Technical Note 1297, Appendix D1 ↗
D.1.1 and D.1.2 explain accuracy and agreement among independent results under stipulated conditions. The lesson interprets original illustrative readings against a reference.
Source consulted 2026-11-17
Lesson lesson.robotics-automation.accuracy-and-repeatability · Revision 1.0.0. Found a problem? Raise a content concern. This prepares a local note; no report is delivered by opening it.